COMPONENTS
ILLUSTRATION
InstallationRemoval
REMOVAL
PROCEDURE
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable
is reconnected (See page ).
2. DISCONNECT CABLE FROM POSITIVE BATTERY TERMINAL
3. REMOVE BAT ...
Low Power Supply Voltage Malfunction (C1241)
DESCRIPTION
If the voltage supplied to the IG1 terminal is within the DTC detection range
due to malfunctions in components such as the battery and generator circuit, this
DTC is stored.
DTC Code
DTC Detection Condition
T ...