To minimize the risk of fuel leakage when the engine stalls or when an airbag inflates upon collision, the fuel pump shut off system stops the supply of fuel to the engine.
Follow the procedure below to restart the engine after the system is activated.
Vehicles without a smart key system
Turn the engine switch to the
“ACC” or “LOCK” position.
Restart
the engine.
Vehicles with a smart key system
Turn the “ENGINE START STOP”
switch off.
Restart the
engine.
NOTICE
Before starting the engine
Inspect the ground under the vehicle.
If you find that fuel has leaked onto the ground, the fuel system has been damaged and is in need of repair. Do not restart the engine.
If you think something is wrongTransmission Fluid Temperature Sensor "A" Circuit Low Input (P0712,P0713)
DESCRIPTION
Refer to DTC P0711 (See page
).
DTC Code
DTC Detection Condition
Trouble Area
P0712
ATF temperature sensor resistance is below 79 Ω for 0.5 sec. or more
(1-trip detection logic ...
Lost Communication with ECM / PCM "A" (U0100)
DESCRIPTION
DTC Code
DTC Detection Condition
Trouble Area
U0100
There is no communication from the ECM.
Power source or inside ECM
ECM main wire or connector
ECM
...