Toyota 4Runner manuals

Toyota 4Runner: Fuel pump shut off system

To minimize the risk of fuel leakage when the engine stalls or when an airbag inflates upon collision, the fuel pump shut off system stops the supply of fuel to the engine.

Follow the procedure below to restart the engine after the system is activated.

Vehicles without a smart key system

Turn the engine switch to the
“ACC” or “LOCK” position.

Restart
the engine.

Vehicles with a smart key system

Turn the “ENGINE START STOP”
switch off.

Restart the
engine.

NOTICE

Before starting the engine

Inspect the ground under the vehicle.

If you find that fuel has leaked onto the ground, the fuel system has been damaged and is in need of repair. Do not restart the engine.

If you think something is wrong
If you notice any of the following symptoms, your vehicle probably needs adjustment or repair. Contact your Toyota dealer as soon as possible. Visible symptoms • Fluid leaks under the vehicle ( ...

Steps to take in an emergency
...

Other materials about Toyota 4Runner:

Fail-safe Chart
FAIL-SAFE CHART 1. POWER WINDOW OPERATION IN FAIL-SAFE MODE HINT: If the pulse sensor built into a power window regulator motor malfunctions, the power window control system enters fail-safe mode. (a) The power window control system prohibits the followi ...

Front Passenger Side Power Window does not Operate with Front Passenger Side Power Window Switch
DESCRIPTION If the manual up/down function does not operate, there may be a malfunction in the power window regulator switch, front power window regulator motor, harness or connector. WIRING DIAGRAM CAUTION / NOTICE / HINT NOTICE: I ...