Toyota 4Runner manuals

Toyota 4Runner: Generator Signal Circuit

DESCRIPTION

When the engine is started, the generator assembly turns on and a voltage pulse signal is generated.

This signal is used by the air conditioning amplifier assembly.

The signal expressing the amount of output from the generator assembly is one element of PTC heater control.

WIRING DIAGRAM


PROCEDURE

1.

CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - GENERATOR)

(a) Disconnect the F42 amplifier connector.

(b) Disconnect the C5 generator connector.

(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

F42-25 (ALT) - C5-3 (M)

Always

Below 1 Ω

F42-25 (ALT) - Body ground

Always

10 kΩ or higher


OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE


NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

Air Conditioning Compressor Magnetic Clutch Circuit
DESCRIPTION When the air conditioning amplifier assembly is turned on, a magnet clutch assembly signal is sent from the MGC terminal of the air conditioning amplifier assembly. Then, the A/C COMP ...

PTC Heater Circuit
DESCRIPTION PTC heater relays are closed in accordance with signals from the air conditioning amplifier assembly and power is supplied to the quick heater assembly installed on the radiator heate ...

Other materials about Toyota 4Runner:

Terminals Of Ecu
TERMINALS OF ECU 1. CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) AND DRIVER SIDE JUNCTION BLOCK ASSEMBLY (a) Remove the main body ECU (multiplex network body ECU) from the driver side junction block assembly (See page ). (b) Measure the resistanc ...

On-vehicle Inspection
ON-VEHICLE INSPECTION PROCEDURE 1. CHECK AUTOMATIC LIGHT CONTROL SENSOR (a) Measure the voltage according to the value(s) in the table below. Standard Voltage: Tester Connection Switch Condition ...

© 2016-2024 | www.to4runner.net