INITIALIZATION
1. ZERO POINT CALIBRATION
NOTICE:
Make sure that the front passenger seat is not occupied before performing the operation.
HINT:
Perform the zero point calibration and sensitivity check if any of the following conditions apply.
(a) Zero point calibration and sensitivity check procedures
HINT:
Make sure that zero point calibration has finished normally before performing the sensitivity check.
(1) Adjust the seat position according to the table below.
Adjustment Component |
Position |
---|---|
Slide Direction |
Rearmost position |
Reclining Angle |
Upright position |
Headrest Height |
Lowest position |
Lifter Height |
Lowest position |
(2) Connect the Techstream to the DLC3.
(3) Turn the ignition switch to ON.
(4) Perform the zero point calibration by following the prompts on the screen.
HINT:
Refer to the Techstream operator's manual for further details.
OK:
"Zero Point Calibration is complete." is displayed.
(5) Perform the sensitivity check by following the prompts on the screen.
(6) Confirm that the beginning sensor reading is within the standard range.
Standard:
-3.2 to 3.2 kg (-7.0 to 7.0 lb)
(7) Place a 30 kg (66.1 lb) weight (eg. a 30 kg (66.1 lb) of lead mass) onto the front passenger seat.
NOTICE:
*1 |
Weight Position |
(8) Confirm that the sensitivity is within the standard range.
Standard:
27 to 33 kg (59.5 to 72.8 lb)
HINT:
AUTO LSD Indicator Light Remains ON
DESCRIPTION
During normal mode, pressing the VSC OFF switch for a short amount of time changes
vehicle to AUTO LSD mode.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE:
When replacing the master cylinder solenoid, perform calibration (See page
).
PR ...
Diagnostic Trouble Code Chart
DIAGNOSTIC TROUBLE CODE CHART
HINT:
If a trouble code is output during the DTC check, inspect the trouble
areas listed for that code. For details of the code, refer to the "See page"
below.
*: The air conditioning amplifier stor ...