INSPECTION
PROCEDURE
1. INSPECT FRONT SEATBACK HEATER ASSEMBLY LH
(a) Check the seatback heater.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
1 - 2 |
Seatback heater temperature 20°C (68°F) |
4.2 to 5.2 Ω |
If the result is not as specified, replace the front seatback heater assembly LH.
Text in Illustration
*a |
Component without harness connected (Front Seatback Heater Assembly LH)) |
2. INSPECT FRONT SEATBACK HEATER ASSEMBLY RH
(a) Check the seatback heater.
(1) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection |
Condition |
Specified Condition |
---|---|---|
1 - 2 |
Seatback heater temperature 20°C (68°F) |
4.2 to 5.2 Ω |
If the result is not as specified, replace the front seatback heater assembly RH.
Text in Illustration
*a |
Component without harness connected (Front Seatback Heater Assembly RH) |
Customize Parameters
CUSTOMIZE PARAMETERS
1. CUSTOMIZING FUNCTION WITH TECHSTREAM (REFERENCE)
HINT:
The following items can be customized.
NOTICE:
When the customer requests a change in a function, first make sure that
the function can be customized.
Record th ...
Precaution
PRECAUTION
1. PRECAUTIONS FOR EACH FUNCTION
(a) Precautions for the key:
The key is a precision instrument. Be sure to observe the following:
(1) Do not drop or strike the key.
(2) Do not keep the key in a high temperature area for a long ...