INSPECTION
PROCEDURE
1. INSPECT GENERATOR WITH CLUTCH PULLEY
(a) Hold the center of the generator with clutch pulley and check that the outer ring turns counterclockwise and does not turn clockwise.
Text in Illustration
Free |
|
Lock |
If the result is not as specified, replace the generator with clutch pulley.
2. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY
(a) Using a vernier caliper, measure the brush length. Standard exposed length: 9.5 to 11.5 mm (0.374 to 0.453 in.) Minimum exposed length: 4.5 mm (0.177 in.) Text in Illustration
If the brush length is less than the minimum, replace the generator brush holder assembly. |
|
3. INSPECT GENERATOR ROTOR ASSEMBLY
(a) Check that the generator rotor bearing is not rough or worn. If necessary, replace the generator rotor assembly. |
|
(b) Check the generator rotor for an open circuit.
(1) Measure the resistance according to the value(s) in the table below. Standard Resistance:
If the result is not as specified, replace the generator rotor assembly. |
|
(c) Check if the generator rotor is grounded.
(1) Measure the resistance according to the value(s) in the table below. Standard Resistance:
If the result is not as specified, replace the generator rotor assembly. |
|
(d) Using a vernier caliper, measure the slip ring diameter. Standard diameter: 14.2 to 14.4 mm (0.559 to 0.567 in.) Minimum diameter: 14.0 mm (0.551 in.) Text in Illustration
If the diameter is less than the minimum, replace the generator rotor assembly. |
|
Wireless Door Lock Tuner Circuit Malfunction (B1242)
DESCRIPTION
The door lock receiver is used to receive electrical waves relating to the entry
functions of the smart key system (for Entry Function). The certification ECU decodes
the requested smart key system (for Entry Function) operation by identifying ...
Backup Battery Degradation (B15EC)
DESCRIPTION
This DTC is stored when the DCM (Telematics Transceiver) detects either of the
following conditions.
The BUB (Back-Up Battery) charge level becomes less than the criteria.
Automatic Collision Notification (ACN) was performed.
...