System DiagramData List / Active Test
DATA LIST / ACTIVE TEST
1. READ DATA LIST
HINT:
Using the Techstream to read the Data List allows the values or states of switches,
sensors, actuators and other items to be read without removing any parts. This non-intrusive
inspection can be very usefu ...
Disassembly
DISASSEMBLY
PROCEDURE
1. REMOVE FRONT UNIVERSAL JOINT SPIDER BEARING
HINT:
Use the same procedure for all front propeller shaft universal joint spider bearing.
(a) Place matchmarks on the flange yoke and sleeve yoke.