DESCRIPTION
The jam protection function operates within a specified range during the manual up or auto up operation.
PROCEDURE
|
1. |
PERFORM INITIALIZATION |
(a) Initialize the power window regulator motor (See page
).
(b) Check if the power window auto up/down function operates (See page
).
OK:
Auto up/down function operates.
| NG | |
GO TO OTHER PROBLEM |
|
|
2. |
CHECK JAM PROTECTION FUNCTION OPERATING RANGE |
(a) Check if the jam protection function operates for applicable power window.
HINT:
The jam protection function does not operate between the fully closed position of the door glass and the position 4 mm (0.157 in.) below that.
OK:
Jam protection function operates.
| OK | |
END |
| NG | |
REPLACE POWER WINDOW REGULATOR MOTOR (APPLICABLE MOTOR) |
Auto Down Operation does not Fully Open Power Window (Catch Protection Function
is Activated)
Power Window Master SwitchCD Sound Skips
PROCEDURE
1.
CHECK CD
(a) Check that the CD is not deformed or cracked.
OK:
No deformation or cracks on the CD
NG
CD IS FAULTY
...
Terminals Of Ecu
TERMINALS OF ECU
1. CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
(a) Disconnect the F42 air conditioning amplifier connector.
(b) Measure the voltage and resistance according to the value(s) in the table
below.
Terminal No. (Symbol)
...