MANUAL SHIFTING TEST
1. MANUAL SHIFTING TEST
HINT:
(a) Disconnect the connector of the transmission wire.
HINT:
It is possible to deactivate the electrical shift control by disconnecting the transmission wire. The gear positions can then be changed mechanically with the shift lever.
(b) Drive with the transmission wire disconnected. Move the shift lever to each position to check whether the gear position changes as shown in the table below.
|
Shift Lever Position |
Gear Position |
|---|---|
|
P |
P |
|
R |
R |
|
D |
4th |
(c) Connect the connector of the transmission wire.
(d) Clear the DTCs (See page
).
Hydraulic Test
InitializationInstallation
INSTALLATION
CAUTION / NOTICE / HINT
HINT:
A bolt without a torque specification is shown in the standard bolt chart (See
page ).
PROCEDURE
1. INSTALL PINTLE HOOK SUPPORT TUBE SUB-ASSEMBLY (w/ Pintle Hook)
2. INSTALL REAR BUMPER UPPER RETAINER LH
...
Low Pressure Malfunction in Upside of KDSS System (C1851/51,C1853/53)
DESCRIPTION
In the KDSS hydraulic circuit, the fluid is contained under pressure. If the
fluid temperature is 20°C (68°F), the pressure is approximately 3.0 MPa (30.6 kgf/cm2,
435 psi).
DTC Code
DTC Detection Condition
...