CUSTOMIZE PARAMETERS
1. CUSTOMIZING FUNCTION WITH TECHSTREAM
NOTICE:
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Enter the following menus: Customize.
(e) Select the setting by referring to the table below.
Wireless Door Lock|
Display (item) |
Default |
Function |
Setting |
|---|---|---|---|
|
Wireless Control |
ON |
The function that turns the wireless door lock on or off. |
ON or OFF |
|
Hazard Answer Back |
ON |
When the lock switch on the transmitter is pressed, this function illuminates the hazard warning lights and side turn signal lights once. When the unlock switch is pressed, the hazard warning lights and side turn signal lights illuminate twice. |
ON or OFF |
|
Open Door Warning |
ON |
If a door is not completely closed and the transmitter lock switch is pressed, this function makes the buzzer sound for 5 seconds. |
ON or OFF |
|
Panic Function |
ON |
The function to operate the theft deterrent system by continuously pressing the panic switch on the transmitter for 0.8 seconds. |
ON or OFF |
|
Auto Lock Time |
60 s |
The function that changes the time until relocking after unlocking the doors with the wireless door lock function. |
30 s, 60 s or 120 s |
|
Wireless Auto Lock |
ON |
This function turns the wireless auto lock function on or off. |
ON or OFF |
|
Wireless Buzzer Resp |
ON |
This function turns the wireless door lock buzzer response on or off. |
ON or OFF |
|
P/W Ope buzzer |
ON |
This function turns the wireless power window buzzer response on or off. |
ON or OFF |
|
Wireless Buzzer Vol |
Level7 |
This function changes the wireless door lock buzzer volume. |
Level7, Level6, Level5, Level4, Level3, Level2, Level1 or Level0 |
How To Proceed With Troubleshooting
Operation CheckTerminals Of Ecu
TERMINALS OF ECU
1. CHECK FRONT POWER SEAT SWITCH LH
(a) Disconnect the b18 and b19 connectors from the front power seat switch LH.
(b) Measure the voltage and resistance according to the value(s) in the table
below.
Terminal No. (Symbol)
...
Accessory Meter
Components
COMPONENTS
ILLUSTRATION
Removal
REMOVAL
PROCEDURE
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-)
battery terminal to disable the SRS system.
N ...