ON-VEHICLE INSPECTION
PROCEDURE
1. INSPECT SEAT HEATER CONTROL SUB-ASSEMBLY LH
|
(a) Disconnect the b2 seat heater control sub-assembly LH connector. |
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
|
b2-6 (E) - Body ground |
Always |
Below 1 Ω |
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
|
Tester Connection |
Switch Condition |
Specified Condition |
|---|---|---|
|
b2-1 (SWL) - b2-6 (E) |
Ignition switch ON Seat heater switch LH off |
Below 1 V |
|
Ignition switch ON Seat heater switch LH on |
11 to 14 V |
|
|
b2-4 (B) - b2-6 (E) |
Ignition switch off |
Below 1 V |
|
Ignition switch ON |
11 to 14 V |
|
*a |
Front view of wire harness connector (to Seat Heater Control Sub-assembly LH) |
If the result is not as specified, there may be a malfunction on the wire harness side.
(d) Connect the b2 seat heater control sub-assembly LH connector.
|
(e) Measure the voltage according to the value(s) in the table below. Standard Voltage:
If the result is not as specified, the seat heater control sub-assembly LH may have a malfunction. |
|
2. INSPECT SEAT HEATER CONTROL SUB-ASSEMBLY RH
|
(a) Disconnect the a2 seat heater control sub-assembly RH connector. |
|
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
|
a2-6 (E) - Body ground |
Always |
Below 1 Ω |
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
|
Tester Connection |
Switch Condition |
Specified Condition |
|---|---|---|
|
a2-1 (SWR) - a2-6 (E) |
Ignition switch ON Seat heater switch RH off |
Below 1 V |
|
Ignition switch ON Seat heater switch RH on |
11 to 14 V |
|
|
a2-4 (B1) - a2-6 (E) |
Ignition switch off |
Below 1 V |
|
Ignition switch ON |
11 to 14 V |
|
*a |
Front view of wire harness connector (to Seat Heater Control Sub-assembly RH) |
If the result is not as specified, there may be a malfunction on the wire harness side.
(d) Connect the a2 seat heater control sub-assembly RH connector.
|
(e) Measure the voltage according to the value(s) in the table below. Standard Voltage:
If the result is not as specified, the seat heater control sub-assembly RH may have a malfunction. |
|
Problem Symptoms Table
Seat Memory SwitchTransmitter ID not Registered (C2171/71)
DESCRIPTION
The ID of each tire pressure warning valve and transmitter is registered to the
tire pressure warning ECU.
When the ECU detects that a transmitter ID code is not registered in the ECU,
this DTC is stored.
DTC Code
Detec ...
Short to GND in Hall Effect Sensor Power Circuit (31)
DESCRIPTION
When there is a short to GND in the side auto step motor hall sensor power circuit,
the side auto step controller ECU assembly does not operate the automatic running
board.
DTC No.
Detection Condition
Trouble ...