Problem Symptoms Table
ComponentsInstallation
INSTALLATION
PROCEDURE
1. INSTALL STABILIZER CONTROL WITH ACCUMULATOR HOUSING ASSEMBLY
(a) Install the stabilizer control with accumulator housing with the 3 bolts.
Torque:
29 N·m {296 kgf·cm, 21 ft·lbf}
(b) Connect the connector, and then attach the ...
Inspection
INSPECTION
PROCEDURE
1. INSPECT FRONT POWER SEAT SWITCH LH
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Slide Switch
Tester Connection
Switch Condition
Specified Conditi ...